GE phoenix v|tome|x L240
• Granite-based 7-axis manipulator for long-term stability and highest precision • Detector: flat panel dynamic 41|100: 4000 x 4000 px, pixel size 100 μm • Air-conditioned cabinet • Cluster of 4 GPUs – faster CT data reconstruction • 240 kV / 320 W microfocus tube • 180 kV / 50 W nanofocus tube Limits • Samples up to 500 x 800 mm and 50 kg • Min. voxel size: 2 µm for 240 kV tube, 1 µm for 180 kV tube
Specification
- Granite-based 7-axis manipulator for long-term stability and highest precision
- Detector: flat panel dynamic 41|100: 4000 x 4000 px, pixel size 100 μm
- Air-conditioned cabinet
- Cluster of 4 GPUs – faster CT data reconstruction
- 240 kV / 320 W microfocus tube
- 180 kV / 50 W nanofocus tube
Limits
- Samples up to 500 x 800 mm and 50 kg
- Min. voxel size: 2 µm for 240 kV tube, 1 µm for 180 kV tube
Publications
POSPIECH, M.; ZIKMUND, T.; JAVŮRKOVÁ, Z.; KAISER, J.; TREMLOVÁ, B., 2019: An Innovative Detection of Mechanically Separated Meat in Meat Products. FOOD ANAL METHOD 12 (3), p. 1 - 6, doi: 10.1007/s12161-018-1394-8 (micro-CT-L240)
KALOVÁ, K.; BOBEROVÁ, K.; PŘICHYSTALOVÁ, R.; NOVÁČEK, J.; JAROŠOVÁ, I.; ZIKMUND, T.; KAISER, J.; KYSELICOVÁ, K.; ŠEBEST, L.; BALDOVIČ, M.; FRTÚS, A.; SIKORA, M.; ALLENTOFT, M., 2019: Serious chronic disease of the cervical spine and trauma in a young female from the middle ages (Czech Republic). INTERNATIONAL JOURNAL OF PALEOPATHOLOGY 24, p. 185 - 12, doi: 10.1016/j.ijpp.2018.11.004 (micro-CT-L240)
ŠŤASTNÝ, P.; CHLUP, Z.; KALASOVÁ, D.; ZIKMUND, T.; KAISER, J.; TRUNEC, M., 2018: Epoxy-based gelcasting of machinable hydroxyapatite foams for medical applications. JOURNAL OF THE AMERICAN CERAMIC SOCIETY 101 (8), p. 3317 - 11, doi: 10.1111/jace.15523 (micro-CT-L240)
TESAŘOVÁ M., MANCINI L., SIMON A., ADAMEYKO I., KAUCKÁ M., ELEWA A., LANZAFAME G., ZHANG Y., KALASOVÁ D., SZAROWSKÁ B., ZIKMUND T., NOVOTNÁ M., KAISER J., 2018: A quantitative analysis of 3D-cell distribution in regenerating muscle-skeletal system with synchrotron X-ray computed microtomography. SCIENTIFIC REPORTS 8, p. 1 - 12, doi: 10.1038/s41598-018-32459-2 (micro-CT-L240)
PROCHAZKA, D.; ZIKMUND, T.; POŘÍZKA, P.; BŘÍNEK, A.; KLUS, J.; ŠALPLACHTA, J.; NOVOTNÝ, J.; KAISER, J., 2018: Joint utilization of double-pulse laser-induced breakdown spectroscopy and X-ray computed tomography for volumetric information of geological samples. JOURNAL OF ANALALYTICAL ATOMIC SPECTROMETRY 33 (11), p. 1 - 7, doi: 10.1039/c8ja00232k (micro-CT-L240, LIBS-FireFly)
SABOLOVÁ, V.; BŘÍNEK, A.; SLÁDEK, V., 2018: The effect of hydrochloric acid on microstructure of porcine (Sus scrofa domesticus) cortical bone tissue. FORENSIC SCIENCE INTERNATIONAL 291, p. 260 - 12, doi: 10.1016/j.forsciint.2018.08.030 (micro-CT-L240)
HEUDE, E.; TESAŘOVÁ, M.; SEFTON, E. M.; JULLIAN, E.; ADACHI, N.; GRIMALDI, A.; ZIKMUND, T.; KAISER, J.; KARDON, G.; KELLY, R. G.; TAJBAKHSH, S., 2018: Unique morphogenetic signatures define mammalian neck muscles and associated connective tissues. ELIFE 7, p. 1 - 26, doi: 10.7554/eLife.40179 (micro-CT-L240)